call-us
Change Language
Bomb Calorimeter (Digital) (With Safety Device)

Bomb Calorimeter (Digital) (With Safety Device)

Product Details:

  • Resolution 0.01C or 1 calorie
  • Temperature Ambient to 40C (Operating)
  • Response Time Within 5 seconds
  • Measuring Range Up to 10,000 Cal/g
  • Port Size Standard Type
  • Display Type Digital LED display
  • Specimen Size Up to 1 gram (solid fuel sample)
  • Click to View more
X

Bomb Calorimeter (Digital) (With Safety Device) Price And Quantity

Bomb Calorimeter (Digital) (With Safety Device) Product Specifications

  • 230 V AC
  • Single specimen at a time
  • Up to 10,000 Cal/g
  • Digital with sensor input
  • Within 5 seconds
  • Digital Bomb Calorimeter (with safety device)
  • Standard Type
  • 50 Hz
  • Up to 10,000 calories
  • 300 ml Water Capacity
  • Oxygen at 30 atm (Required for operation)
  • Microprocessor based digital control
  • 0.01C or 1 calorie
  • Approx. 45 cm
  • Determining calorific value of solid & liquid fuels
  • Ambient to 40C (Operating)
  • Automatic safety device, automatic water filling, digital temperature display
  • 230V AC, 50Hz
  • 0.1% of reading
  • Table Top
  • Up to 1 gram (solid fuel sample)
  • Digital LED display

Bomb Calorimeter (Digital) (With Safety Device) Trade Information

  • Yes
  • Sample costs shipping and taxes has to be paid by the buyer
  • South America, Africa, Central America, Eastern Europe, Australia, Middle East, Western Europe, Asia, North America
  • All India
  • ISO Certification, MSME Certificate

Product Description

Bomb Calorimeter (Digital) (With Safety Device)

For determination of heat combustion of organic mater and calorific value and sulphur content of coal, solid and liquid fuels. The bomb has a capacity of 300 ml approximately a provided with a high pressure schroder valve. Test as per the recruitment of Institute of Petroleum (IP 12/63T). Supplied with bomb calorimeter vessel with bomb support, water jacket, combined lid for calorimeter vessel and water jacket, stirrer, commenting leads, connecting tube to connect to pressure gauge. Connecting tube spanner for oxygen tube connection, ignition wire (2 meter) Nicrome, cotton reel, stand for unit, pellets press, digital backman, thermometer benzoic acid, 'O' ring small, 'O' ring for stirrer. Valve for bomb and valve key. Supplied without oxygen cylinder.



Advanced Control and Safety Features

The bomb calorimeter is equipped with a microprocessor-based digital control system and a digital LED display for clear, precise readings. It incorporates an automatic safety device, automatic water filling, and an electric ignition system for operational safety and ease. The robust stainless steel construction and nickel/quartz crucibles ensure durability and chemical compatibility, making this unit suitable for routine laboratory use.


Accurate Performance and Compliance

Factory-calibrated with a benzoic acid standard, the calorimeter maintains an impressive accuracy of 0.1% of reading, with a sensitive resolution of 0.01C or 1 calorie. The system complies with ASTM D240, IS 1350, and related standard test methods, meeting industry requirements for energy content analysis of fuels. The design supports reliable results whether in academic, industrial, or research laboratory environments.

FAQs of Bomb Calorimeter (Digital) (With Safety Device):


Q: How does the Digital Bomb Calorimeter determine the calorific value of fuels?

A: The calorimeter measures the heat produced by the complete combustion of a sample (up to 1 gram) in a controlled oxygen atmosphere at 30 atm. The sample is placed in a nickel or quartz crucible, ignited electrically, and the resulting temperature change in the surrounding water jacket is measured digitally to calculate the calorific value.

Q: What are the benefits of the built-in safety device and automatic features?

A: The integrated safety device provides enhanced protection by monitoring pressure and operation conditions, minimizing the risk of accidents. Automatic water filling and digital temperature display streamline the process, reducing user intervention and increasing operational efficiency and convenience.

Q: When should I calibrate or check the calibration of the instrument?

A: The device is factory-calibrated using a benzoic acid standard and typically requires recalibration annually or after extensive use. Follow the manufacturers guidelines for regular calibration checks to ensure continued accuracy and reliability.

Q: Where can the bomb calorimeter be installed and operated?

A: Designed as a table-top unit, it is suitable for laboratories in academic, industrial, or research settings. Ensure the space accommodates its dimensions (approx. 50 x 38 x 45 cm) and provides an accessible power supply (230V AC, 50 Hz) with adequate ventilation and safety measures for oxygen gas handling.

Q: What is included in the delivery scope of the calorimeter?

A: The package consists of the bomb calorimeter unit, pressure gauge, ignition wire, nickel or quartz crucible, digital controller, utility accessories, and a comprehensive instruction manual for setup and operation.

Q: How do I operate the calorimeter for a test?

A: Place the fuel sample in the crucible, seal it in the combustion vessel, and fill with oxygen at 30 atm. Use the digital control to initiate ignition. The device will automatically monitor the process and display results, including temperature rise and calculated calorific value.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Oil & Petroleum Testing Instruments' category